ASTM D1056 gives buyers and suppliers a shared shorthand for sponge and expanded rubber. The shorthand has changed over the decades, and a few characters on a drawing can decide whether two foams are really interchangeable.
An engineer specifies "ASTM D1056 2C1" for a die-cut gasket. A supplier responds with a data sheet marked "SCE-41," while another offers "VE-41" because its compression-deflection value falls within the same range. The three labels look related, but they do not automatically describe interchangeable materials.
For buyers of closed-cell foam, the important questions are which standard and edition apply, what the complete callout requires, and whether the proposed grade has been tested for the intended use. This guide explains the codes and shows what to confirm before releasing a drawing or requesting a quotation.
What ASTM D1056 Covers
ASTM D1056-20, the current active edition, specifies flexible cellular materials known as sponge rubber and expanded rubber. It covers open-cell and closed-cell rubber materials made from natural, synthetic, reclaimed or blended elastomers, subject to its scope. It does not cover latex foam rubber or ebonite cellular rubber.
The standard organizes materials by type, class and grade, with suffix requirements for additional characteristics. It includes test provisions concerning compression deflection, aging, fluid exposure, water absorption and other properties. It is a material specification, not a guarantee that a finished gasket, flotation component or protective pad is suitable for a particular application.
ASTM also notes that small extruded or molded shapes may not provide standard-sized test specimens. When a detailed product specification conflicts with the general specification, the detailed requirements take precedence. A buyer ordering thin die-cut parts should therefore agree on the specimen and test approach before treating sheet-material values as finished-part acceptance criteria.
Decoding 2C1: Cell Structure, Oil Response and Firmness
The three characters in 2C1 each have a different purpose.
| Character | Meaning | What it tells the buyer |
| 2 | Type 2: closed-cell rubber | The material belongs to the closed-cell category in ASTM D1056 |
| C | Class C: specified oil resistance with medium mass change | A performance classification for oil exposure, not the name of a polymer |
| 1 | Grade 1: 25% compression deflection of roughly 2-5 psi (15-35 kPa) | The force range associated with compressing the test specimen by 25% |
The class letter should not be read as a resin identifier. Class A does not require a particular level of resistance to petroleum-based oils; B and C designate differing oil-response requirements; D addresses an extreme-temperature class. Common examples include EPDM for A, some nitrile formulations for B, and neoprene or certain blends for C. Actual classification depends on tested material performance, not a polymer label alone. Cooper Standard's classification guide provides the underlying distinctions.
Grade 1 is about compression deflection, not compression set. Compression deflection describes the force needed to compress a specimen by a defined amount. Compression set concerns permanent deformation after a specified compression and recovery procedure. A foam may be soft enough for Grade 1 yet recover differently after prolonged compression. That difference matters for sealing applications.
Why the Suffixes Cannot Be Left Off a Quote
A short callout such as 2C1 narrows the material category, but a drawing may also specify supplementary tests. The supplier should identify the exact suffix letters and numbers in the applicable edition and report the corresponding results.
| Common D1056 suffix family | Property considered | Example of why it matters |
| A | Heat resistance | Foam near heated equipment or piping |
| B | Compression set | Gaskets held under load for extended periods |
| C | Weather or ozone resistance | Outdoor seals or exposed components |
| E | Fluid resistance | Parts exposed to specified oils or fluids |
| F | Low-temperature resistance | Cold storage or outdoor installations |
| J | Water absorption | Buoyancy, wet environments or moisture-sensitive uses |
| K | Flammability resistance | Products with an applicable flame-performance requirement |
| Z | Special agreed requirements | Buyer-defined tests not captured by a standard suffix |
The letter alone does not provide the full acceptance limit. For example, a drawing that calls out an additional compression-set requirement needs the applicable suffix designation and a corresponding test result, not a data-sheet statement that a foam has "good recovery." The Cooper Standard reference gives an example of an extended callout, 2C2 A1 B2 E1 Z.
For foam used as insulation, protective padding or flotation, additional application tests may be needed even when the basic ASTM classification matches. Density alone cannot confirm long-term buoyancy; a compression-deflection value alone cannot confirm impact protection or seal durability.
Does the Old SCE-41 Code Equal Today's 2C1?
SCE-41 is a legacy designation appearing on data sheets written against older ASTM D1056 editions. Many cross-reference tables associate SCE-41 with the later 2C1 classification, and some suppliers list both codes for the same grade. That association is useful for identifying candidate materials, but it is not a blanket equivalence statement.
All Seals' material listings show products described under legacy SCE-41 with newer classifications including 2C1 and, for some blends, 2A1. Likewise, the exact properties and test provisions can vary by edition. A converter chart cannot replace the original drawing requirement or an actual test record.
For a legacy drawing, ask for:
- The year of the ASTM D1056 edition used for the original SCE-41 callout.
- The complete old specification, including any additional suffixes and product-specific requirements.
- The candidate material's current D1056 classification, with the test edition and results.
- Written approval from the design authority if a material substitution changes the applicable specification.
If the original design records are incomplete, label the new material as a proposed alternative pending validation, not a confirmed drop-in replacement.
VE-41 Belongs to a Different ASTM Standard
VE-41 is a designation under ASTM D1667-22, the current edition for specified flexible closed-cell poly(vinyl chloride) foam materials. D1667 covers products whose elastomer content is predominantly PVC or relevant copolymers; it is not merely a renamed section of D1056.
In the D1667-22 grade table, VE-41 has a 25% compression-deflection range of 15-35 kPa, similar to the Grade 1 range under D1056. The resemblance stops short of proving equivalence. The standards have different material scopes, test provisions and associated requirements. The published D1667-22 grade table confirms the VE-41 range.
| Code on the drawing or data sheet | Standard family | What can be inferred | What still needs checking |
| 2C1 | ASTM D1056, newer designation | Closed-cell rubber, Class C oil response, Grade 1 compression deflection | Edition, suffixes, actual measured values and application requirements |
| SCE-41 | Older ASTM D1056 designation | A legacy closed-cell foam callout | Original edition and documented cross-reference to a modern grade |
| VE-41 | ASTM D1667 | Closed-cell PVC-family foam with a Grade 41 compression-deflection band | Chemistry, full D1667 requirements and suitability as an alternative to the drawing material |
For procurement, the safe interpretation is simple: matching a 2-5 psi firmness range does not establish matching oil resistance, compression recovery, water uptake or service performance.
A Real Supplier Example: Reading Winboss Foam Tables
Taiwan-based Winboss Industrial publishes insulation and cushioning foam specifications with sheet dimensions, density, 25% compression deflection, compression set and water absorption. It also lists both ASTM D1056-68 and D1056-91 codes for several grades. This makes its table useful for seeing how a buyer should compare properties beyond a short code.
Selected values from the manufacturer's published category table include:
| Winboss grade | Published 25% compression deflection | Listed D1056-68 code | Listed D1056-91 code |
| AP-702CF | 1.5-4.0 psi | SCE-41 | 2C1 |
| TAPE | 2.5-5.0 psi | SCE-41 | 2C1 |
| NV-904S | 3.5-5.0 psi | SCE-41 | 2B1 |
These figures illustrate why a purchasing team should not rely on a cross-reference alone. Winboss lists SCE-41 alongside 2C1 for some grades and 2B1 for NV-904S. Its AP-702CF table also gives a lower end of 1.5 psi, below the common 2 psi lower bound for Grade 1. The page notes that some ASTM methods may have been modified for end-use evaluation.
Those observations do not establish that a material is nonconforming. They identify details to clarify with the manufacturer: which edition and method support the classification, whether the published figures are typical ranges or acceptance limits, and what test data apply to the ordered grade and thickness. This is especially important before copying a website table directly into an approved material specification.
Winboss also references UL component recognition for flame-resistant foam under file E238526. Buyers requiring a particular flame rating should confirm the covered grade, thickness, conditions and recognition scope rather than treat a category-level statement as approval for every finished part.
What to Send With a Closed-Cell Foam RFQ
An RFQ should describe the part and the environment as clearly as it describes the material code.
| RFQ item | Information to provide or request |
| Specification | Full ASTM designation, edition year, type/class/grade and all suffixes |
| Material identity | Approved polymer family or blend restrictions; clarify whether D1056 or D1667 is intended |
| Geometry | Drawing, nominal thickness, tolerance, sheet or roll requirements, die-cut features and adhesive backing |
| Compression performance | 25% compression-deflection results, compression-set criteria, test method and specimen conditions |
| Exposure | Oils, cleaning agents, temperature range, outdoor weather, moisture or continuous immersion |
| Application-specific requirements | Water absorption, thermal performance, flame characteristics, or other needed tests |
| Quality evidence | Current data sheet, grade and thickness identification, test reports and sample approval process |
When two suppliers propose "2C1" grades, compare their measured results under comparable test conditions, not only their pass/fail labels. For small gasket strips, agree whether the acceptance test is performed on a parent sheet, a standard specimen, or a specially prepared sample. The test arrangement can affect whether the results are directly comparable.
Frequently Asked Questions
Q: What does ASTM D1056 2C1 mean?
A: It identifies a Type 2 closed-cell cellular rubber, Class C oil-response category and Grade 1 compression-deflection range of approximately 2-5 psi (15-35 kPa). Additional suffix requirements may apply.
Q: Are SCE-41 and 2C1 interchangeable?
A: Not automatically. SCE-41 is a legacy designation frequently associated with newer 2C1 materials, but the relevant edition and full properties must be verified for the specific product.
Q: Can VE-41 replace a 2C1 gasket?
A: Only after approval against the application's requirements. VE-41 is classified under ASTM D1667 for PVC-family foam, while 2C1 belongs to ASTM D1056. Similar compression deflection does not prove equivalent performance.
Q: Does a 2C1 code guarantee low compression set?
A: No universal compression-set value can be inferred from those three characters alone. Check the complete specification, any required suffix and the supplier's actual compression-set results.
Q: What if a supplier's table contains both old and new codes?
A: Request the edition-specific test evidence, confirm which code is used for current orders, and resolve any differences before approving the material or substituting it into an existing drawing.
Final Considerations
The first three characters of a cellular-foam callout help narrow the material selection, but they do not replace a full engineering specification. 2C1, SCE-41 and VE-41 differ in standard, edition, or both. A defensible purchasing decision checks the complete code, test conditions, polymer family and final-part requirements before treating supplier options as equivalent.
For buyers reviewing real product data, Winboss' insulation and cushion foam specifications provide published examples of compression, water absorption and historical ASTM codes. The most useful next step is to request grade-specific evidence and clarify any legacy-to-current designation differences against the actual drawing.